City of Miami Beach, Chapter 54, Article III
Seawall Height Requirements in Miami Beach
Seawall height requirements in Miami Beach are in Chapter 54 of the city code. A new wall, or an existing wall that needs substantial improvements, has a 5.7 foot NAVD88 minimum.
Which number fits your wall?
It depends on the work. New wall, or substantial improvements to an old one: 5.7 feet. Improvements that count as less than substantial can stop at 4 feet NAVD88, but only if the wall is designed and built to take a future 5.7.
Who decides what's substantial? City staff, from an itemized cost breakdown of the seawall work that comes with the permit application.
Small maintenance, like adding rip-rap, is exempt from the minimum if an engineering report satisfies the city that the wall is structurally sound.
The city adopted these rules on January 13, 2021, in an ordinance titled "Resiliency Standards for Tidal Flood Protection," and rewrote parts of them on July 23, 2025.
Permits on Miami Beach
The city's own announcement named four approvals for a seawall replacement: the U.S. Army Corps of Engineers, the State of Florida, the county and the city. Ask your contractor who files each one.
Not in Miami Beach? Ask the contractor what your city requires. The county permit side is on our Miami-Dade seawall contractor page.
What the Miami Beach City Code says
Current text of Chapter 54, Article III, as amended by Ordinance No. 2025-4754 (July 23, 2025). Paragraph (c) of Sec. 54-62 is left out. Typos ("is this article", "fee") are in the code as published.
Sec. 54-59. - Purpose and intent.
The purpose of this article is to protect the public's health, welfare and safety by establishing minimum standards to be used in the design, construction and maintenance of waterfront structures. This article establishes a minimum elevation for new seawalls and requires failing and low seawalls, bulkheads, living shorelines, or other shoreline protection structures that cause tidal surface water flooding to adjacent properties to be properly maintained, repaired or, if necessary, replaced. The physical seawall improvements ensure new seawalls, bulkheads, living shorelines, or other shoreline protection structures are designed to meet consistent standards that account for future tidal flood conditions and coastal water levels predicted with sea level rise, in accordance with current regional sea level rise projections, as updated and adopted by the city commission.
(Ord. No. 2021-4393, § 1, 1-13-21; Ord. No. 2025-4754, § 1, 7-23-25)
Sec. 54-60. - Applicability.
Mandatory compliance with the requirements of this article shall be required for the following types of building permit applications:
(1) All new waterfront construction and substantial improvements;
(2) All new seawalls; and
(3) Substantial improvements, including repair or rehabilitation, to existing shorelines and shoreline structures.
Each applicant shall submit documentation including an itemized breakdown of the costs of construction specific to the seawall work to allow city staff to determine whether improvements are substantial and to evaluate compliance with the minimum elevation requirements.
Mandatory compliance with the requirements of this article shall be required for all low seawalls, bulkheads, living shorelines, or other shoreline protection structures that do not meet the minimum standards is this article, except as otherwise provided in this article; and any other existing condition that causes tidal surface water flooding onto adjacent properties and/or public right-of-way. This article is not applicable to oceanfront beaches or shorelines seaward of the Coastal Construction Control Line.
Sec. 54-62. - Minimum elevations and materials for new or substantially rehabilitated coastal infrastructure within tidally-influence areas.
(a) All new seawalls or existing seawalls that require substantial improvements; shall have a minimum elevation of 5.7 feet NAVD88. All existing seawalls that require improvements that are considered less than substantial improvements shall have a minimum elevation of four feet NAVD88, but only if designed and constructed to accommodate a future minimum elevation of 5.7 fee NAVD88. Notwithstanding the foregoing sentence, limited maintenance work, such as the installation of rip-rap, shall be exempt from the minimum elevation requirement in this section, provided that an engineering report is submitted that demonstrates, to the satisfaction of the city, that the seawall is structurally sound. All existing seawalls constructed at a height that allows flooding to incur onto the upland property, an adjacent property, and/or public right-of-way shall have a minimum elevation of four feet NAVD88 if designed and constructed to accommodate a minimum elevation of 5.7 feet NAVD88.
(b) To the extent practicable, seawalls shall be designed and constructed to adjoin immediately proximate seawalls to close gaps and prevent trespass of tidal surface water.
(d) This section shall not be construed to require the installation of a seawall where other flood protection measures and living shorelines serve as an equally effective tidal flood barrier.